    StoneLite® Installation Instructions

    For more installation videos, click here.

    StoneLite® panels can be attached in several different ways depending on the application and back up framing. Below are links to instructions for our most commonly used attachment systems. To determine the best and most economical attachment system for your specific application, please contact us at (800) 328-6275.

    Interlocking Channel System

    Interlocking Channel SystemOur Interlocking Channel System is our most commonly used attachment system. It is extremely versatile, working well with a variety of back up systems on both exterior and interior applications. This very simple attachment system offers extremely fast construction speed greatly reducing field labor. For a full explanation of this system with additional photos DOWNLOAD PDF.

    SP1 Wide Interlocking Channel Detail

    SP2 Narrow Interlocking Channel Detail

    Joint Interlocking Channel System

    Joint Interlocking Channel SystemOur Joint Interlocking Channel System is a variation of our interlocking channel system developed to assist with joint alignment and to eliminate the need for much of the field channel normally required by incorporating it into the panel below. For detailed instructions on installing with this system DOWNLOAD PDF.

    SP3 Wide Interlocking Joint Channel

    SP4 Narrow Interlocking Joint Channel

    Adhesive Attachment

    Adhesive AttachmentOn many interior applications, the most economical way to attach StoneLite® Panels is to simply adhere them directly to the drywall, steel stud framing, or existing backup. Installation is very quick and simple, greatly reducing on-site labor costs. For instructions on using adhesive to install our panels DOWNLOAD PDF.

    SP16 Interior Adhesive Attachment over Gypsum Wallboard Detail

    SP17 Interior Structural Silicone over Steel Stud Framing/Furring Detail

    SP18 Adhesive Attachment over Existing Surface Detail

    Edge Plate Attachment

    Our Edge Plate attachment system is one of our simplest systems. Each panel is shipped with factory attached edge plates around the panel edges. Attachment is made by screwing through the joints through the slotted hole in the anchor plate and into the framing behind. This system requires that framing be located behind each panel joint and the minimum joint size is 3/8″ (10 mm) as all attachments are made through the joints. For detailed instructions on installing with this system DOWNLOAD PDF.

    SP12 Edge Plate Attachment Detail

    SP13 Edge Plate Attachment Isometric View Detail

    Zee Section

    Zee SectionOur Zee section attachment system is an optional interior attachment system. Each panel is shipped with factory attached zee sections. Mating sections are then screwed to the wall and the panels drop into place. This very simple attachment system offers extremely fast construction speed greatly reducing field labor. For detailed instructions on installing with this system DOWNLOAD PDF.

    SP42 Attachment Details